Welcome to Shanghai Huiming Fluid! Shanghai Huiming Fluid Control Equipment Co., Ltd. operates various water pump products. The main products are: centrifugal pumps , self-priming pumps , sewage pumps , magnetic pumps , vacuum pumps , chemical pumps , diaphragm pumps , oil pumps , multi-stage pumps , canned pumps , screw pumps. , Submersible pumps , submersible pumps , metering pumps , pump control cabinets , water supply equipment , etc. Water pump products are widely used in various fields such as water conservancy, construction, fire protection, electricity, environmental protection, petroleum, chemical industry, etc.

product list

product search

Shanghai Huiming Fluid Control Equipment Co., Ltd. provides you with the best service, the most complete product introduction and the best product quality!

contact details

Phone: 021-66620000
Fax: 021-51685787
Email: 51685787@myfax.cn
Website: http://fotobrio.com
Your present location: Huiming Fluid >> Products >> Magnetic pump >> CQB-G type high temperature magnetic drive centrifugal pump
Pump Catalog

CQB-G type high temperature magnetic drive centrifugal pump

CQB-G type high temperature magnetic drive centrifugal pump
Submit Order Online Sales Hotline: 021-66620000 Inquiry Fax: 021-551685787

product name: CQB-G type high temperature magnetic drive centrifugal pump <br /> Caliber (import / export): 32-100 / 20-65 (mm)
flow: 1.9-120 (m3 / h)
Head: 7.5-86 (m)

Product Overview:
CQB-G type high temperature heat preservation pump adopts multiple circulation cooling structure to ensure the reliability and stability of the motive force and magnetic transmission. At the same time, the use of pin coupling reduces the noise and vibration of the pump, and the dismountable and pin coupling At the same time, the structure of the pump is increased, which is more conducive to the heat dissipation of the pump. At the same time, it is also very convenient for users to repair or replace parts. The outer rotor part of the pump is also designed with cooling fins to ensure the stability of the magnetic steel. This series of pumps are suitable for conveying high temperature media, and the temperature is ≤300 ℃.
The design of the pump has the characteristics of high reliability, long service life, and high generalized procedures. The magnetic drive pump is also known as a shaftless seal. It replaces the dynamic seal with a static seal, so that the overcurrent parts of the pump are completely sealed. Coupling transmission, so it can replace the original mechanical pump mechanical seal has been unable to solve the problems of running, running, dripping, leaking.
Meaning of model:
        CQB-G100-80-160
CQB Magnetic Drive Pump
G high temperature
100 pump inlet diameter
80 pump outlet diameter
160 pump impeller nominal diameter
Performance parameters

Type
caliber
flow
(L / min)
Head m
Motor Power
KW
Rotating speed
(r / min)
Voltage
(V)
Import (mm)
Exit (mm)
CQB32-20-125G
32
20
3.2
20
1.5
2900
380
CQB32-20-160G
32
2.2
2900
380
CQB40-25-125G
40
25
6.3
20
2.2
2900
380
CQB40-25-160G
32
3
2900
380
CQB40-25-200G
50
5.5
2900
380
CQB50-32-125G
50
32
12.5
20
3
2900
380
CQB50-32-160G
32
4
2900
380
CQB50-32-200G
50
7.5
2900
380
CQB50-32-250G
80
15
2900
380
CQB65-50-125G
65
50
25
20
5.5
2900
380
CQB65-50-160G
32
7.5
2900
380
CQB65-40-200G
40
50
15
2900
380
CQB65-40-250G
80
twenty two
2900
380
CQB80-65-125G
80
65
50
20
7.5
2900
380
CQB80-65-160G
32
15
2900
380
CQB80-50-200G
50
50
twenty two
2900
380
CQB80-50-250G
80
37
2900
380
CQB100-80-125G
100
80
100
20
15
2900
380
CQB100-80-160G
32
twenty two
2900
380
CQB100-65-200G
65
50
37
2900
380
CQB100-65-250G
80
55
2900
380
 
Fourth, installation and commissioning

(2) When the pumping liquid level is higher than the axis of the fruit axis. Open the valve of the suction pipe before starting. If the pumping liquid level is lower than the axis of the pump axis, the pipe must be equipped
Foot valve.
(3) The pump should be checked before use. The fan of the motor should be flexible to rotate. There should be no jamming and abnormal noise. All fasteners should be tightened.
(4) Check whether the rotation direction of the motor is consistent with the magnetic pump steering mark.
(5) After the motor starts, slowly open the discharge valve. After the pump enters the normal working state, adjust the discharge valve to the required opening.
Before the pump stops working, close the discharge valve first, then cut off the power, and then close the cooling water pipe valve
V. Precautions for use:
 
(1) Because the cooling and lubrication of the magnetic pump bearings rely on the conveyed medium, dry running is absolutely forbidden. At the same time, it is necessary to avoid empty running when the power is turned off and restarted in the middle of work.

(2) If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet: if it contains ferromagnetic particles, a magnetic filter should be added.

(3) The medium to be transported and its temperature shall be within the range of the allowable parts of the pump material. Pump operating temperature <280 ° C, maximum working pressure of 1.6MPa, density of not more than 1840kg / m3, viscosity of not more than 30cm2 / S, no hard particles and dimensional liquid. Special working conditions should be strictly in accordance with the contract agreement.

(4) For the transporting medium which is easy to deposit and precipitate, it should be cleaned in time after use to drain the liquid in the pump.

(E) After 1000 hours of normal operation of the magnetic pump, the bearing and the end face moving ring should be disassembled and inspected, and the unusable & damaged parts should be replaced.

(VI) The magnetic coupling inside and outside of this series of pumps uses high-performance permanent magnet materials, which may cause potential harm to the following devices. Please keep the following devices away from this series of pumps. Such as: cardiac pacemakers, credit cards and other magnetic cards, calculators, computer disks, watches, etc.

6. Faults and troubleshooting:

Failure form

cause

Method of exclusion

No water from the pump

Water pump reverse

2. Air leak in the water inlet pipe

3. Insufficient water storage by pumping

4. The voltage is too high. The coupling slips when starting

5. Suction is too high

6. Valve does not open

1. Change the motor wiring

2. Avoid leaks

3. Increase water storage

4. Adjust the voltage

5. Lower the pump installation position

6. Calibrate or change the valve

Insufficient traffic

1. The suction pipe diameter is too small or blocked

2. Impeller flow path is blocked

3. Head is too high

4. Not enough speed

1. Exchange or clean the water inlet pipe

2.washing wheel

3. Open the large water outlet valve

4. Restore the rated speed

Head is too low

1. Excessive traffic

2.Speed is too low

1.Close the small water outlet valve

2. Restore the rated speed

Too noisy

1Severely damaged pump shaft

2.Severely damaged bearings

3. The outer magnetic steel or inner magnetic steel is in contact with the insulation sleeve

4.Seal ring and impeller grinding

5. Wear of rolling bearings in the cooling box

1. Replace the pump shaft

2. Replace the bearing

3. Remove the pump head and reassemble

4. Replace the thrust ring. Seal ring

5. Replace the rolling bearing

Leakage

 type seal is damaged

Replace O-ring