Welcome to Shanghai Huiming Fluid! Shanghai Huiming Fluid Control Equipment Co., Ltd. operates various water pump products. The main products are: centrifugal pumps , self-priming pumps , sewage pumps , magnetic pumps , vacuum pumps , chemical pumps , diaphragm pumps , oil pumps , multi-stage pumps , canned pumps , screw pumps. , Submersible pumps , submersible pumps , metering pumps , pump control cabinets , water supply equipment , etc. Water pump products are widely used in various fields such as water conservancy, construction, fire protection, electricity, environmental protection, petroleum, chemical industry, etc.

product list

product search

Shanghai Huiming Fluid Control Equipment Co., Ltd. provides you with the best service, the most complete product introduction and the best product quality!

contact details

Phone: 021-66620000
Fax: 021-51685787
Email: 51685787@myfax.cn
Website: http://fotobrio.com
Your present location: Huiming Fluid >> Products >> Magnetic pump >> CQ type magnetic drive pump
Pump Catalog

CQ type magnetic drive pump

CQ type magnetic drive pump
Submit Order Online Sales Hotline: 021-66620000 Inquiry Fax: 021-551685787

product name: CQ type magnetic drive pump
Caliber (import / export): 14-100 / 10-80 (mm)
flow: 1.2-60 (m3 / h)
Head: 5-50 (m)

CQ type magnetic drive pump ( referred to as magnetic pump) is a new product that applies the working principle of permanent magnet coupling to centrifugal pumps. It has reasonable design, advanced technology, full seal, no leakage, corrosion resistance, etc., and its performance reaches abroad. Advanced level of similar products.

I. Main features:

The magnetic pump replaces the dynamic seal with a static seal, so that the overcurrent parts of the pump are completely sealed, which completely solves the problems of running, running, and dripping that other pump mechanical seals cannot avoid. The magnetic pump uses corrosion-resistant, high-strength engineering plastics, steel-jade ceramics, and stainless steel as manufacturing materials, so it has good corrosion resistance and can protect the conveyed medium from pollution.

Product use:

The magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation and convenient use and maintenance. Can be widely used in chemical, pharmaceutical, petroleum, electroplating, food, film photofinishing, scientific research institutions, defense industry and other units to pump acid, lye, oil, rare precious liquid, venom, volatile liquid, and supporting equipment for circulating water, Matching filter. Especially for pumping leaking, flammable and explosive liquids, this pump is more ideal.

Third, installation and use:

1. The magnetic pump should be installed horizontally and should not be erected. The plastic pump body must not bear the weight of the pipeline. For vertical installation with special requirements, the motor must face upward.
2. When the pumping liquid level is higher than the pump shaft centerline, open the suction pipe valve before starting. If the pumping liquid level is lower than the pump shaft take-up line, the pipe must be equipped with a bottom valve.
3. The pump should be checked before use. The motor blades must be flexible to rotate, no jamming and noisy sounds, and all fasteners must be fastened.
4. Check whether the motor rotation direction is consistent with the magnetic pump steering mark.
5. After the motor starts, slowly open the discharge valve. After the pump enters the normal working state, adjust the discharge valve to the required opening.
6. Before the pump stops working, close the discharge valve first, and then close the valve of the suction pipe.
 

4. Faults and troubleshooting:

1.Because the cooling and lubrication of the magnetic pump bearings rely on the medium being transported, dry running is absolutely forbidden. At the same time, no-load running is caused when the power is turned off and restarted during the work.
2. If the conveyed medium contains solid particles, a filter must be added to the pump inlet: if it contains ferromagnetic particles, a magnetic filter must be added.
3. The ambient temperature of the pump in use should be less than 40 ° C, and the temperature rise of the motor must not exceed 75 ° C.
4. The conveyed medium and its temperature should be within the allowable range of the pump material. The operating temperature of engineering plastic pumps is <60 ° C, the operating temperature of metal pumps is <100 ° C, the auxiliary suction pressure is not greater than 0.2MPa, the maximum working pressure is 1.6MPa, the density is not greater than 1600 ^ kg / m3, and the particle size is not greater than 30 X 10 -6㎡ / S liquid without hard particles and fibers.
5. For the medium that is easy to precipitate and crystallize, the transport liquid should be cleaned immediately after use to drain the liquid accumulated in the pump.
6. After 500 hours of operation of the magnetic pump, the wear and inertia of the bearing and the end-moving ring should be disassembled. If the gap between the bearing and the sleeve is greater than 0.5 ~ 1mm, the impeller moves axially 1. 5 ~ 2mm, the bearing and Axial moving ring.

Five, model meaning:

Five, performance parameters:

model
Caliber (mm)
flow
(m3 / h)
Head
(m)
Cavitation allowance
(NPSH) r (m)
Motor Power
(KW)
Rotating speed
(r / min)
voltage
(V)
import
Export
14CQ-5
14
10
1.2
5
6.0
0.12
2900
220/380
16CQ-8
16
12
1.8
8
6.0
0.18
220/380
20CQ-12
20
12
3
12
6.0
0.37
220/380
25CQ-15
25
20
5.4
15
6.0
1.10
380
32CQ-15
32
25
6.6
15
6.0
1.10
380
32CQ-25
32
25
4.8
25
5.5
1.10
380
40CQ-20
40
32
10.8
20
4.0
2.2
380
40CQ-32
40
32
11.5
32
4.0
4
380
50CQ-25
50
40
14.4
25
4.0
4
380
50CQ-40
50
40
13.2
40
4.0
4
380
50CQ-50
50
32
7.8
50
4.0
5.5
380
65CQ-25
65
50
16.8
25
4.0
5.5
380
65CQ-32
65
50
27
32
4.0
7.5
380
80CQ-20
80
65
50
20
4.0
7.5
380
80CQ-35
80
65
50
35
4.0
11
380

Six, magnetic pump shape and installation dimensions

model
A
B
C
D
E
L
H
h
b
W
K
X
a
Machine base
Screw hole
P
P1
Q
Q1
ф1
ф2
Note
14CQ-5
90
71
75
125
55
325
145
62
ф18
110
130
51
ф22
ф7
tube
connection
16CQ-8
90
71
75
125
55
325
145
62
ф18
110
130
51
ф22
ф7
20CQ-12
100
80
105
120.5
59.5
310
160
73
ф18
150
160
51
ф26
ф9
25CQ-15
125
100
140
189.5
67.5
460
205
90
180
240
71.5
ф11
75
65
100
90
12
10
Flange connection
32CQ-15
125
100
140
189.5
67.5
460
205
90
180
240
71.5
ф11
90
75
120
100
14
12
32CQ-25
125
100
140
189.5
67.5
460
230
90
180
253
80
ф11
90
75
120
100
14
12
40CQ-20
140
125
155
243
78
580
210
100
205
290
78.5
ф12
100
90
130
120
14
14
40CQ-32
190
140
190
271
80
620
260
112
245
336
91
ф12
100
90
130
120
14
14
50CQ-25
190
140
190
271
80
620
260
112
245
336
91
ф12
110
100
140
130
14
14
50CQ-40
216
140
210
335
80
720
315
132
280
340
91
ф12
110
100
140
130
14
14
50CQ-50
216
140
210
331
84
715
306
132
280
350
91
ф12
110
90
140
120
14
14
65CQ-25
216
140
210
290
80
695
280
132
280
350
91
ф12
130
110
160
140
14
14
65CQ-32
216
140
210
395
76
770
295
132
280
350
91
ф12
130
110
160
140
14
14
25CQ-16-40
125
100
190
193
68
505
205
90
160
290
72
ф12
85
75
115
100
14
14
High-pressure pump
40CQ-32-40
160
140
195
275
85
650
260
110
200
345
95
ф12
110
100
115
135
16
16
50CQ-40-40
216
140
200
330
80
750
300
132
280
336
95
ф12
125
100
160
135
16
16

下一页: Previous Page: CQB Type Magnetic Drive Centrifugal Pump Next Page:
CQ type magnetic drive pumpCQB type magnetic drive centrifugal pumpZCQ type self-priming magnetic pump Miniature magnetic drive circulation pump
Sales address: No. 301, Yuanhe Road, Yueyang Industrial Park, Baoshan, Shanghai Tel: 021-66620000 Fax: 021-551685787
CopyRight © 2013 Shanghai Huiming Fluid Control Equipment Co., Ltd. All rights reserved
天天电玩城 欢乐拼三张 七乐彩 手机电玩平台