Welcome to Shanghai Huiming Fluid! Shanghai Huiming Fluid Control Equipment Co., Ltd. operates various pump products. The main products are: centrifugal pumps , self-priming pumps , sewage pumps , magnetic pumps , vacuum pumps , chemical pumps , diaphragm pumps , oil pumps , multi-stage pumps , canned pumps , screw pump , Submersible pumps , submersible pumps , metering pumps , pump control cabinets , water supply equipment , etc. Water pump products are widely used in various fields such as water conservancy, construction, fire protection, electricity, environmental protection, petroleum, chemical industry, etc.

product list

product search

Shanghai Huiming Fluid Control Equipment Co., Ltd. provides you with the best service, the most complete product introduction and the best product quality!

contact details

Phone: 021-66620000
Fax: 021-51685787
Email: 51685787@myfax.cn
Website: http://fotobrio.com
Your present location: Huiming Fluid >> Products >> Centrifugal Pump >> S, SH Single-stage Double Suction Centrifugal Pump
Pump Catalog

S, SH single-stage double suction centrifugal pump

S, SH single-stage double suction centrifugal pump
Submit Order Online Sales Hotline: 021-66620000 Inquiry Fax: 021-551685787

product name: S, SH type single stage double suction pump <br /> Product Category: Centrifugal pump
Caliber (import / export): 100-800mm
flow: 72-5500m3 / h
Head: 10-125m

Product Overview:

S, SH type single-stage double-suction centrifugal pump opened in the casing for pumping clean water or other liquids with similar physical and chemical properties to water The temperature of the liquid to be transported must not be higher than 80 ° C. Suitable for factories, mines, urban water supply, power stations, farmland drainage and irrigation and various water conservancy projects.

Structure chart:

Serial number

name

Serial number

name

1

Pump body

12

Bushing nut (right)

2

Pump cover

13

Bearing body

3

Pump shaft

14

Fixing bolts

4

impeller

15

Bearing body gland

5

Double suction seal ring

16

Coupling parts

6

Sleeve

17

Round nut

7

Packing sleeve

18

Bearing cover (A)

8

Water-sealed tube

19

Bushing nut (left)

9

filler

20

Bearing retaining ring

10

Packing ring

twenty one

Bearing cover (B)

11

Packing gland

twenty two

End cap

3. Meaning of model:

Fourth, assembly, disassembly, installation:

Assembly and disassembly
1. Assemble rotor parts: install impeller, shaft sleeve, shaft sleeve nut, packing sleeve, packing ring, packing gland, water retaining ring and bearing components on the pump shaft in order, put double suction seal ring, and then install Coupling.
2. Install the rotor component on the pump body, adjust the axial position of the impeller to the middle of the double suction seal rings on both sides to fix it, and fasten the bearing body gland with the fixing screw.
3. Put the stuffing on, put the paper pad on it, cover the pump cover and tighten the stud pin, then tighten the pump cover nut, and finally install the grave gland. But don't press the packing too tightly. If the packing is too tight, it will cause the shaft sleeve to heat up and consume a large amount of power. Don't press too loosely. If it is too loose, it will cause large liquid leakage and reduce the efficiency of the pump.
After the assembly is completed, the pump shaft is rotated by hand without rubbing. The rotation is relatively smooth and even, and the disassembly can be performed in the opposite order of the assembly.
installation
1. Check that the water pump and motor are not damaged.
2. The installation height of the pump, plus the hydraulic loss of the suction pipe, and its speed energy, must not be greater than the allowable suction height value specified in the sample. The basic dimensions should conform to the installation dimensions of the pump unit.
3. Installation sequence:
① Place the water pump on the concrete foundation with anchor bolts, adjust the level by adjusting the wedge-shaped spacer in between, and tighten the anchor bolts appropriately to prevent walking.
② Put concrete after foundation and pump feet.
③ After the concrete is dry, tighten the anchor bolts and check the level of the pump again.
④ Correct the concentricity of the motor shaft and the pump shaft. Make the two axes in a straight line, the tolerance of the coaxiality on the outer circle of the two-axis device is 0.1mm, and the tolerance of the unevenness of the end gap along the circumference is 0.3mm , Should still meet the above requirements).
⑤ After checking that the rotation of the motor is consistent with that of the pump, install the coupling and the connecting pin.
4. Support for the inlet and outlet water pipes shall be provided separately, and shall not be supported by the pump body.
5. The junction between the pump and the pipeline should ensure good air tightness, especially the water inlet pipeline, must be strictly non-leakage, and there should be no possibility of air trapping on the device.
6. If the water pump is installed above the inlet water level, a bottom valve can be installed to start the pump. Can also be used to vacuum water.
7. After the pump and the water outlet pipe, generally need to install the gate valve and check valve (the head is less than 20 meters can be used), the check valve is installed behind the gate valve. The installation method mentioned above refers to the pump unit without a common base.
Install the pump with a common base, and adjust the level of the unit by adjusting the wedge-shaped horn between the base and the concrete foundation. Concrete is then poured in between. Its installation principles and requirements are the same as for units without a common base.

Five, start, stop and run:

1. Start and stop:
Before starting, turn the rotor of the pump, it should be smooth and even.
② Close the water gate valve and fill the pump (if there is no bottom valve, use a vacuum pump to evacuate water) to ensure that the pump is full of water. No air is trapped.
③ If the pump is equipped with a vacuum gauge or pressure gauge, turn off the rotary base connected to the pump and restart the motor. Turn it on after the speed is normal; then gradually open the water gate valve. If the flow is too large, you can properly close the small gate valve Adjust; otherwise, the flow is too small. Open the gate valve.
④ Tighten the compression nut on the packing gland evenly to make the liquid leak out. At the same time, pay attention to the temperature rise at the packing cavity.
⑤ When stopping the pump operation, first close the cocks of the vacuum gauge and pressure gauge, and the gate valve on the water outlet pipe. Then turn off the power to the motor.
When the temperature in the environment is low, the square screw plug in the lower part of the pump body should be opened. Remove the water to prevent frost cracking. ⑥ When it is not used for a long time, the water pump should be disassembled and the water on the other parts should be wiped dry. Apply rust preventive oil on the processed surface for safekeeping.
2. Operation:
① The maximum temperature of the pump bearing should not exceed 75 ° C.
② The amount of calcium-based butter used to lubricate the bearing is preferably 1/3 to 1/2 of the bearing body space.
③ Packing gland can be properly pressed when the packing is worn. If it is too worn, it should be replaced.
④ Regularly check the shaft parts. Pay attention to the temperature rise of the motor bearings.
⑤ During operation, if snoring or other abnormal sounds are found, stop immediately, check the cause, and eliminate it.
⑥ Do not increase the speed of the pump arbitrarily. However, it can be used at a reduced speed. For example, the rated speed of this pump is n flow is Q, head is H. Shaft power is N, reduced speed is n1. Flow after reduced speed. It is Q1, H1 and N1. Their relationship. It can be converted by the following formula:
Q1 = (n1 / n) Q H1 = (n1 / n) ²H N1 = (n1 / n) ³N

Five, pump performance parameters:

model
flow
Head
Rotating speed
Power (KW)
effectiveness
Cavitation allowance
(m3 / h)
(m)
(r / min)
Shaft power
Motor Power
(%)
(m)
100S90
80
90
2950
30.1
37
65
2.5
100S90A
72
75
twenty three
30
64
2.5
150S100
160
100
59.8
75
73
3.5
150S78
160
78
45
55
73.5
3.5
150S78A
144
62
33.8
45
72
3.5
150S50
160
50
27.3
37
80
3.9
150S50A
144
40
20.9
30
75
3.9
150S50B
133
36
18.6
twenty two
70
3.9
200S95
280
95
91.7
110
79.2
5.3
200S95A
270
75
73.5
90
75
5.3
200S63
280
63
58.3
75
82.7
5.8
200S63A
270
46
45.1
55
75
5.8
200S42
280
42
38.1
45
84.2
6
200S42A
270
36
33.1
37
80
6
250S65
485
65
1450
109
132
78.6
3
250S65A
468
54
89.4
110
77
3
250S39
485
39
61.5
75
83.6
3.2
250S39A
468
30.5
49.3
55
79
3.2
250S24
485
twenty four
36.9
45
85.8
3.5
250S24A
414
20.3
27.6
37
83
3.5
250S14
485
14
21.5
30
85.8
3.8
250S14A
432
11
15.8
18.5
82
3.8
300S110
790
110
295.7
440
80
4
300S90
790
90
242.8
315
79.6
4
300S90A
756
78
217
280
74
4
300S90B
720
67
180
220
73
4
300S58
790
58
149.9
180
84.2
4.4
300S58A
720
49
118.6
160
81
4.4
300S58B
684
43
100
132
80
4.4
300S32
790
32
79.2
110
86.8
4.6
300S32A
720
26
60.7
75
84
4.6
300S19
790
19
47
55
86.8
5.2
300S19A
720
16
39.2
45
80
5.2
300S12
790
12
30.4
37
84.8
5.5
300S12A
684
10
3.9
30
78
5.5
350S125
1260
125
534
710
80.5
5.4
350S125A
1181
112
462
630
78
5.4
350S125B
1098
96
373
500
77
5.4
350S75
1260
75
303
355
85.2
5.8
350S75A
1170
65
247
280
84
5.8
350S75B
1080
55
197
220
82
5.8
350S44
1260
44
173
220
87.5
6.3
350S44A
1116
36
131
160
84
6.3
350S26
1260
26
102
132
87.5
6.7
350S26A
1116
21.5
78.8
90
83
6.7
350S16
1260
16
64.5
75
85.3
7.1
350S16A
1044
13.4
48.8
55
48
7.1
500S98
2020
95
970
678
800
79.5
4
500S98A
1872
83
540
630
78.5
4
500S98B
1746
74
452
560
78
4
500S59
2020
59
391
450
83
4.5
500S59A
1872
49
333
400
75
4.5
500S59B
1746
40
257
315
74
4.5
500S35
2020
35
219
280
88
4.8
500S35A
1746
27
151
220
85
4.8
500S22
2020
twenty two
144.1
185
84
5.2
500S22A
1746
17
101
132
80
5.2
500S13
2020
13
86.2
110
83
5.7
600S75
3170
75
727
800
89
7.5
600S75A
2880
65
580
630
88
7.5
600S47
3170
47
465
560
88
7.5
600S32
3170
32
310
400
89
7.5
600S32A
2880
27
238
280
89
7.5
600S22
3170
twenty two
223
280
85
7.5
600S22A
2880
18.2
168.5
200
84.5
7.5

CDLF stainless steel stamping multi-stage centrifugal pump ISG single-stage single-suction centrifugal pump ISW horizontal pipeline centrifugal pump Centrifugal pump ZX series horizontal self-priming centrifugal pump DL series vertical multistage centrifugal pump GDL vertical multistage pipeline centrifugal pump SFB, SFBX stainless steel corrosion resistant centrifugal pump CHLF, CHLF (T) light segment multistage centrifugal Pumps CHL, CHLK light stainless steel multistage centrifugal pumps DSW stainless steel horizontal single stage centrifugal pumps
Sales address: No. 301, Yuanhe Road, Yueyang Industrial Park, Baoshan, Shanghai Tel: 021-66620000 Fax: 021-551685787
CopyRight © 2013 Shanghai Huiming Fluid Control Equipment Co., Ltd. All rights reserved
天天电玩城 欢乐拼三张 七乐彩 手机电玩平台